IMPEDANCE BONDS DTM-0,17-1000М AND DTM-0,6-1000М
Impedance bonds of types DTM-0,6-1000M and DTM- 0,17-1000M are designed for installation at metro railway sections equipped with AC automatic locking and DC electric traction under conditions of tunnels and open exits.
Impedance bonds of types DTM-0,6-1000M and DTM- 0,17-1000M are designed for installation at metro railway sections equipped with AC automatic locking and DC
electric traction under conditions of tunnels and open exits.
The impedance bonds are designed for conducting DC rated for 1000 A in the electric traction through each section of the main winding. The center winding lead is designed to amperage of 2000 A.
The impedance bonds operate in the temperature range from - 50°C to + 45°C and produced in U climatic version, category I per GOST 15150-69. Degree of ingress protection is IP54 per GOST 14254.
In terms of personnel protection against electric shock the device is related to class 0 per GOST 12.2.007.0.
electric traction under conditions of tunnels and open exits.
The impedance bonds are designed for conducting DC rated for 1000 A in the electric traction through each section of the main winding. The center winding lead is designed to amperage of 2000 A.
The impedance bonds operate in the temperature range from - 50°C to + 45°C and produced in U climatic version, category I per GOST 15150-69. Degree of ingress protection is IP54 per GOST 14254.
In terms of personnel protection against electric shock the device is related to class 0 per GOST 12.2.007.0.
Product type | Designation in situ | Transformation function | Coefficient | Overall dimensions, mm | Weight, kg |
DТМ-0,6-1000М | YUKLYA.672113.015 | Metro tunnels | 40 | 840×500×400 | 268,5 |
DТМ-0,6-1000М | YUKLYA.672113.015-01 | Metro open exits | 40 | 840×500×400 | 268,5 |
DТМ-0,17-1000М | YUKLYA.672113.011 | Metro tunnels | 40 | 840×500×400 | 262 |
DТМ-0,17-1000М | YUKLYA.672113.011-01 | Metro open exits | 40 | 840×500×400 | 262 |