IMPEDANCE BOND DTM-0,17-1500М
Impedance bond of type TDM-0,17-1500M is designed for installation at metro railway sections equipped with AC automatic locking and DC electric traction under conditions of tunnels and open exits.
Impedance bond of type TDM-0,17-1500M is designed for installation at metro railway sections equipped with AC automatic locking and DC electric traction under conditions of tunnels and open exits.
The impedance bond is designed for conducting DC rated for 1500 A in the electric traction through each section of the main winding. The center winding lead is designed to amperage of 3000 A.
The impedance bond operates in the temperature range from - 50°C to + 45°C and produced in U climatic version, category I per GOST 15150-69.
According to location conditions per allowable mechanical and climatic impacts the impedance bond falls into classifi cation groups MS2 and K4 per OST 32.146.
Degree of ingress protection is IP54 per GOST 14254.
In terms of personnel protection against electric shock the device is related to class 0 per GOST 12.2.007.0.
The impedance bond is designed for conducting DC rated for 1500 A in the electric traction through each section of the main winding. The center winding lead is designed to amperage of 3000 A.
The impedance bond operates in the temperature range from - 50°C to + 45°C and produced in U climatic version, category I per GOST 15150-69.
According to location conditions per allowable mechanical and climatic impacts the impedance bond falls into classifi cation groups MS2 and K4 per OST 32.146.
Degree of ingress protection is IP54 per GOST 14254.
In terms of personnel protection against electric shock the device is related to class 0 per GOST 12.2.007.0.
Product type | Designation in situ | Transformation function | Coefficient | Overall dimensions, mm | Weight, kg |
DТМ-0,17-1500М | UYKLYA.672113.025 | Metro tunnels | 40 | 800×500×400 | 280 |
DТМ-0,17-1500М | UYKLYA.672113.025-01 | Metro open exits | 40 | 800×500×400 | 262 |