IMPEDANCE BONDS 2 DT-1-150, 2 DT-1-300

Impedance bonds are designed for installation at railways sections equipped with automatic locking with marking current frequency of 25 or 75 Hz in the track circuit and AC electric traction of 50 Hz.

Leave a request

By submitting the form, I agree with rules

Your message was sent successfully!

We will contact you as soon as possible.

Error!

Failed to send your message.

Impedance bonds are designed for installation at railways sections equipped with automatic locking with marking current frequency of 25 or 75 Hz in the track circuit and AC electric traction of 50 Hz.

The impedance bonds are designed for conducting AC rated for 150 A and 300 A in the electric traction through each section of the main winding. The center winding lead is designed to amperage of 300A and 600 A.

The impedance bonds operate in the temperature range from - 50°C to + 45°C and produced in U climatic version, category 1 per GOST 15150-69.

Degree of ingress protection is IP43 per GOST 14254.

The devices in terms of personnel protection against electric shock are related to class 0 per GOST 12.2.007.0. Impedance bond 2DT-1-150 in its case replaces two impedance bonds DT-1-150 and the 2DT-1-300 in its case replaces two impedance bonds DT-1-300.
Impedance bond type Designation Coefficient Overall dimensions, mm Weight, kg Electric traction type
2DТ-1-150 YUKLYA.672113.004 520×520×310 88 alternating 
2DТ-1-300 YUKLYA.672113.006 500×500×310 100 alternating 

Other products

Search