Sensor DBL-M, DBP-M

The non-contact sensor of DB type is designed for monitoring gate position in electric switch mechanism SP-6BM and converting obtained information into an electric value to be transmitted to the control station.

Leave a request

By submitting the form, I agree with rules

Your message was sent successfully!

We will contact you as soon as possible.

Error!

Failed to send your message.

The non-contact sensor of DB type is designed for monitoring gate position in electric switch mechanism SP-6BM and converting obtained information into an electric value to be transmitted to the control station.

The sensors are made of two types:
- DBLM — YUKLYA.407529.003 — left;
- DBPM— YUKLYA.407529.003-01 — right.

The sensors are differentiated by designation DBLM and DBPM on the face panel near the strap. The sensor is designed for operation under conditions of direct impact
of the environment contaminated with standard quantity of industrial gases and dust in the temperature range from – 45°C to + 55°C at relative humidity up to 100% at temperature + 25°C (U version, category 1 per GOST 15150-69). Basic technical characteristics of sensor upon switched on load (a relay of type ANVSH2-2400 switched on through a divider).

Sensors are adjusted at rotation angle 115° ± 30’ of rotorsector and under AC voltage of frequency 50 Hz at input coils 24 V and at the signal coil (65+2) V.

ADDITIONAL PARAMETERS

Characteristics Initial position control,
0 ° ± 5 °
Mid-position control,
60 ° ± 12 ° 
Changed over position control,
120 ° ± 5 °
Voltage at input coils, V
(connector contacts 3, 4)
20/24/28 20/24/28 20/24/28
Voltage at signal coil, V
(connector contacts 1, 2)
maximum 3,0/3,5/4,0 maximum 6,0/6,5/7,0 minimum 183/214/243
Consumption AC, A,
maximum
0,25/0,3/0,4 0,3/0,35/0,45 0,45/0,55/0,6 
Overall dimensions, mm: 122×81×170
Switchgear weight, kg, maximum: 3,15
Rated voltage of alternating current, 50 Hz, V : 24±4